Guest
Login
Register
My Cart
(
0
)
My Wishlist
(
0
)
Filters
Home
Search
0
Wishlist
Account
Offers
Brands
Category
Orders
(1 found)
0
My Cart
$
0.00
0
My Wishlist
View Wishlist
Guest
My Account
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
0
Login
•
Register
Shop By Categories
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
My Cart
(
0
)
My Wishlist
(
0
)
MCD-USD-DIRECT
AED Public pricelist
$ MCD-USD-DIRECT
Categories
Categories
See All
Food Safety
Shop
1 items found.
All Products
- 1 items
Pricelist :
MCD-USD-DIRECT
Public pricelist
MCD-USD-DIRECT
Measuring range
-50 to +275°C
+40 to +200 °C
-30 to +220 °C
-50 to +250 °C
-50 to +300 °C
-50 to +275 °C
0 to +60 °C (Short-term to +80 °C max. 5 min)
-30 to +650°C
-30 to +50 °C
-50 to +150 °C
-40 to +125 °C
-30 to +90 °C
-40 to +220 °C
-195 to +1350 °C
-40 to +1000 °C
-50 to +205 °C
-30 to +100°C; 0 to +650°C
-30 to +100° C; 0 to +650° C
-20 to +280 °C
-20 to +70 °C
-35 to +55 °C
-30 to +70 °C
-35 to +70 °C
-80 to +70 °C
-20 to +50 °C/td 0 to +50 °C
-10 to +70 °C/td -40 to +70 °C
-10 to +60 °C
-50 to +125 °C
-50 to +70 °C
-50 to +120 °C
-80 to +300 °C
-100 to +400 °C
-50 to +400 °C
-85 to +150 °C
-100 to +260 °C
0 to +80 °C
0 to +100 °C
+1 to +100 m/s
-40 to +1200 °C
-30 to +400°C
-50 to +350 °C
-150 to +150 hPa
0 to +200 hPa
-200 to +800 °C
-30 to +210 °C
-20 to +55 °C
-30 to +100°C; 0 to +350 °C (switchable)
-20 to +60 °C
-30 to +400 °C
-30 to +100 °C; 0 to +650 °C
-20 to +60 °C / 0 to 100 %RH
0 to 100 hPa
-40 to +150 °C
Accuracy
+/-0.5°C (-20 to +100°C)
+/-1% of mv (+100.0 to +275°C)
±1.0 °C (-50 to -20.1 °C)
±1.5 °C
±0.5 °C (-30 to +99.9 °C)
±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-30 to +99.9 °C) ±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-20 to +100 °C) ±1 % of mv (+100.1 to +275 °C) ±1.0 °C (-50 to -20.1 °C)
±1 °C (-50.0 to -30.1 °C) ±1 % of mv (Remaining Range) ±0.5 °C (-30.0 to +99.9 °C)
±1.0 °C (-50 to -30.1 °C) ±1 % of mv (+100 to +250 °C) ±0.5 °C (-30 to +99.9 °C)
±0.4 °C
±0.5 °C ±0.5 % of mv (-50 to -30 °C) ±0.5 °C ±0.5 % of mv (+70 to +300 °C) ±0.5 °C (-30 to +70 °C)
±1 % of mv (+100 to +275 °C) ±1.0 °C (-50 to -30.10 °C) ±0.5 °C (-30 to +99.9 °C)
±2 °C, ±2 % of m.v.; (greater value applies)
±0.5 °C
±0.3 °C
±0.5 % of mv (100 to +125 °C) ±0.4 °C Remaining Range ±0.2 °C (-25 to +80 °C)
±0.2 °C (-30 to +50 °C)
±0.5 °C (Remaining Range) ±0.2 °C (0 to +70 °C)
Class 1 ¹⁾
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
Class 1 According to standard EN 60584-2
±(0.5 + 0.5 % of mv) °C
Class 2 type K
±2 °C, ±2 % of mv
±0.5 °C (-20 to +70 °C)
±0.5 °C (-35 to +55 °C) ±1 Digit
±0.8 °C (-80 to -35.1 °C) ±0.5 °C (-35 to +70 °C)
±0.5 °C (at +25 °C)
±0.2 °C (-25 to +74.9 °C)
±0.5 % of mv (+100 to +150 °C)
±0.4 °C (Remaining Range)
±0.2 °C (-25 to +80 °C)
±0.2 °C (-25 to +70 °C)
±0.4 °C (-50 to -25 °C)
±(0.1 °C + 0.05 % of mv) (-40 to -0.001 °C)
±0.05 °C (0 to +100 °C)
±0.3 °C (-80 to -40.001 °C)
±(0.05 °C + 0.05 % of mv) (100.001 to 300 °C)
±(0.15 °C + 0.05 % of mv) (0 to +100 °C)
±(0.15 °C + 0.2 % of mv) (+100.01 to +350 °C)
±(0.5 °C + 0.5 % of mv) (+350.01 to +400 °C)
±(0.15 °C + 0.2 % of mv) (-100 to -0.01 °C)
±(0.3 °C + 0.3 % of mv) (-50 to +300 °C)
±(0.4 °C + 0.6 % of mv) (+300.01 to +400 °C)
0.01 °C
±(0.25 °C + 0.3% of reading) at -49.9 to +99.9 °C
±0.55 °C remaining measuring range
±1 °C (-20 to +85 °C)
±0.5 °C (0 to +99 °C)
±0.5 °C (-30 to +70 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C)
±1 °C (-50 to +99.9 °C)
±0.05 hPa (0 to 1.00 hPa) ±0.2 hPa + 1.5 % of mv (1.01 to +150 hPa)
±(0.1 hPa + 1.5 % of mv)± 1 digit (25.001 to 200 hPa); ±(0.3 Pa + 1 % of mv)± 1 digit (0 to 25 hPa)
±0.2 % of mv (Remaining Range) ±0.2 °C (-100 to +199.9 °C)
±2 °C or ±2 % of mv (Remaining Range) ±1.5 °C or ±1.5 % of mv (-20 to +210 °C)
±0.4 °C (-20 to +55 °C) ±1 Digit
±0.8 °C (-20 to 0 °C) ±0.5 °C (0 to +70 °C)
-35 to +70 °C
±0.5 °C (0 to +60 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C) ±2 °C or ±2 % of mv (-30 to 0 °C) (the higher value applies)
<= ±5 %RH (90 to < 100 %RH) <= ±1 %rF Hysterese <= ±3 %RH (10 to < 35 %RH) <= ±0.06 %RH/K (0 to 60 °C) <= ±3 %RH (65 to < 90 %RH) <= ±2 % of mv (35 to < 65 %RH) <= ±5 %RH (0 to < 10 %RH) <= ±1 %rF/year Drift
±0.5 °C ±1 Digit
±(0.1 hPa + 1.5 % of mv) ±1 Digit (25.001 to 200 hPa) ±(0.3 Pa + 1 % of mv) ±1 Digit (0 to 25 hPa)
±3.0 %RH at + 25 °C and < 20 and > 80 %RH ±1.0 %RH / year drift ±2.0 %RH at + 25 °C and 20 to 80 %RH ±1.0 %RH hysteresis // ±0.5 °C ±1 Digit
±2.0 %RH at +25 °C and 20 to 80 %RH ±1.0 %RH / year drift ±1.0 %RH hysteresis ±3.0 %RH at +25 °C and < 20 and > 80 %RH / ±0.5 °C
±0.5 °C / 0 to 100 %RH
± 0,5 °C
±0.03 hPa (0 to 0.30 hPa) ±0.05 hPa (0.31 to 1.00 hPa) ±(0.1 hPa + 1.5 % of m.v.) (1.01 to 100 hPa)
±1.3 °C (-20 to +85 °C)
Resolution
0.1 °C
0.001 °C
0.01 °C
0.1 °C (1 to +100 °C)
0.01 hpa
0.001 to 0.1hPa
0.05 °C
-30 to +100°C; 0 to +350 °C (switchable)
0.001 hPa
0.1 °C / 0.1 %RH
Weight
162 g (incl. batteries) 210 g (incl. belt clip and batteries)
255 g
46 g (including battery)
198 g (incl. batteries)
165 g (incl. batteries)
115 g (with TopSafe) 65 g (without TopSafe)
210 g (incl.battery and Softcase) 154 g (incl. battery, without softcase)
80 g
156.6 g
135 g
69 g
66 g
824 g
595 g
240 g
36 g
1g
385 g
119 g
510 g
250 g
150 g
34 g
130 g
35 g
22 g
44 g
826 g
168 g
1 kg
1243 g
3435 g
258 g
528 g
606 g
322 g
628 g
726 g
261 g
346 g
670 g
182 g
154 g
1190 g
609 g
484 g
99 g
223 g
366 g
16 g
187 g
4800 g
400 g
3136 g
544 g
650 g
76 g
94 g
235 g
955 g
960 g
440 g
200 g
1.3 kg
Dimension
148 x 38 x 185 mm (with attached probe) 148 x 38 x 73 mm (without probe)
170 x 50 x 300 mm ((LxWxH))
189 x 35 x 19 mm (probe folded out)
115 x 35 x 19 mm (probe folded away)
189 x 35 x 19 mm (probe folded out) 115 x 35 x 19 mm (probe folded away)
281 x 48 x 23 mm (Probe folded out) 178 x 48 x 23 mm (probe folded away)
163 x 47 x 20 mm (probe folded away) 265 x 47 x 20 mm (Probe folded out)
197 x 35 x 20 mm ((LxWxH)) 110 x 33 x 20 (without probe and TopSafe)
60 x 42 mm
80 x 90 x 75 mm (LxWxH)
20 x 24 x 140 mm (LxWxH)
570 x 470 x 210 mm (LxWxH)
Operating temperature
-20 to +70 °C
0 to +50 °C
-20 to +60 °C
-20 to +50 °C
0 to +60 °C
-10 to +50 °C
-30 to +50 °C
35 to +55 °C
-35 to +70 °C
-80 to +70 °C
-10 to +70 °C
-10 to +60 °C
-5 to +45 °C
0 to +600 °C
-5 to +50 °C
-30 to 70 °C
Product-/housing material
ABS
TPE/PC + ABS/PC + ABS + 10% GF
ABS / TPE / PC, diecast zinc, stainless steel
Plastic
Stainless Steel
silicone
Metal housing
TPE PC
Protection class
IP65
IP55
IP68
IP67 with TopSafe
IP54
IP30
IP20
IP67
IP40
IP65 with TopSafe
Battery type
Button cell LR44
2 batteries type micro AAA 1.5 V (LR03)
2 lithium batteries (CR2032)
2 AAA micro batteries
1 x CR2032
3 AAA micro batteries
3V button cell (CR 2032)
4 x Button cell LR44
2 x 3V button cell (CR 2032)
3 x AIMn type AAA or Energizer
Lithium battery TLH-2450, 3V, exchangeable
4 x type AA batteries
9V block battery, 6F22
Built-in rechargeable battery: LI batttery 18650; Replaceable battery: 3 alkaline batteries AA
Lithium-Ion rechargeable battery pack, 2600 mAh, 3.7 V
3x AA
lithium batteries
Built-in rechargeable battery: LI batttery 18650; 3x AA; Replaceable battery: 3 alkaline batteries AA
Reaction time
Approx. 30 s
t₉₉ = 10 s (Measured in moving liquid)
10 s (Measured in moving liquid)
8s
t₉₀ = 12 s
7 s
1 s
20 s
t₉₀ = 30 min
t₉₉: 60 s
t₉₉: 10 s
t₉₀ <45 s
240 s
30 s
RESET
Add to Cart
testo 270 BT - Frying oil tester with Bluetooth
$
408.17
408.17
USD