Guest
Login
Register
My Cart
(
0
)
My Wishlist
(
0
)
Filters
Home
Search
0
Wishlist
Account
Offers
Brands
Category
Orders
0
My Cart
AED
0.00
0
My Wishlist
View Wishlist
Guest
My Account
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
0
Login
•
Register
Shop By Categories
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
My Cart
(
0
)
My Wishlist
(
0
)
Categories
Categories
See All
Food Safety
Data Logger
HVAC
Refrigeration
Thermal Imager
Calibration
Emission
Shop
163 items found.
All Products
- 163 items
Pricelist :
Public pricelist
Public pricelist
Price
-
FILTER
Measuring range
-50 to +275°C
+40 to +200 °C
-30 to +220 °C
-50 to +250 °C
-50 to +300 °C
-50 to +275 °C
0 to +60 °C (Short-term to +80 °C max. 5 min)
-30 to +650°C
-30 to +50 °C
-50 to +150 °C
-40 to +125 °C
-30 to +90 °C
-40 to +220 °C
-195 to +1350 °C
-40 to +1000 °C
-50 to +205 °C
-30 to +100°C; 0 to +650°C
-30 to +100° C; 0 to +650° C
-20 to +280 °C
-20 to +70 °C
-35 to +55 °C
-30 to +70 °C
-35 to +70 °C
-80 to +70 °C
-20 to +50 °Ctd 0 to +50 °C
-10 to +70 °C -40 to +70 °Ctd
-10 to +60 °C
Accuracy
+/-0.5°C (-20 to +100°C)
+/-1% of mv (+100.0 to +275°C)
±1.0 °C (-50 to -20.1 °C)
±1.5 °C
±0.5 °C (-30 to +99.9 °C)
±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-30 to +99.9 °C) ±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-20 to +100 °C) ±1 % of mv (+100.1 to +275 °C) ±1.0 °C (-50 to -20.1 °C)
±1 °C (-50.0 to -30.1 °C) ±1 % of mv (Remaining Range) ±0.5 °C (-30.0 to +99.9 °C)
±1.0 °C (-50 to -30.1 °C) ±1 % of mv (+100 to +250 °C) ±0.5 °C (-30 to +99.9 °C)
±0.4 °C
±0.5 °C ±0.5 % of mv (-50 to -30 °C) ±0.5 °C ±0.5 % of mv (+70 to +300 °C) ±0.5 °C (-30 to +70 °C)
±1 % of mv (+100 to +275 °C) ±1.0 °C (-50 to -30.10 °C) ±0.5 °C (-30 to +99.9 °C)
±2 °C, ±2 % of m.v.; (greater value applies)
±0.5 °C
±0.3 °C
±0.5 % of mv (100 to +125 °C) ±0.4 °C Remaining Range ±0.2 °C (-25 to +80 °C)
±0.2 °C (-30 to +50 °C)
±0.5 °C (Remaining Range) ±0.2 °C (0 to +70 °C)
Class 1 ¹⁾
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
Class 1 According to standard EN 60584-2
±(0.5 + 0.5 % of mv) °C
Class 2 type K
±2 °C, ±2 % of mv
±0.5 °C (-20 to +70 °C)
±0.5 °C (-35 to +55 °C) ±1 Digit
±0.8 °C (-80 to -35.1 °C) ±0.5 °C (-35 to +70 °C)
±0.5 °C (at +25 °C)
Measuring rate
0.5 s
2 measurements per second
10 s - 24 h
1 min - 24 h
1 min to 24 h
18 s
20 s
Infrared resolution
0.1 °C
320 x 240 pixel
160 x 120 pixels
Battery Life
100 days (at 15 mins measurement rate)
250 h with no illumination, no Bluetooth<sup>®</sup>; 100 h with illumination and Bluetooth<sup>®</sup>
approx. 1 year
With built-in rechargeable battery:; ≥220 h without Bluetooth®, without illumination; ≥120 h with Bluetooth® and illumination; With 3 AA batteries:; ≥145 h without Bluetooth®, without illumination; ≥75 h with Bluetooth® and illumination
Weight
162 g (incl. batteries) 210 g (incl. belt clip and batteries)
255 g
46 g (including battery)
198 g (incl. batteries)
165 g (incl. batteries)
115 g (with TopSafe) 65 g (without TopSafe)
210 g (incl.battery and Softcase) 154 g (incl. battery, without softcase)
80 g
156.6 g
135 g
69 g
66 g
824 g
595 g
240 g
36 g
1g
385 g
119 g
510 g
250 g
150 g
34 g
130 g
35 g
22 g
44 g
826 g
168 g
1 kg
1243 g
Dimension
148 x 38 x 185 mm (with attached probe) 148 x 38 x 73 mm (without probe)
170 x 50 x 300 mm ((LxWxH))
189 x 35 x 19 mm (probe folded out)
115 x 35 x 19 mm (probe folded away)
189 x 35 x 19 mm (probe folded out) 115 x 35 x 19 mm (probe folded away)
281 x 48 x 23 mm (Probe folded out) 178 x 48 x 23 mm (probe folded away)
163 x 47 x 20 mm (probe folded away) 265 x 47 x 20 mm (Probe folded out)
197 x 35 x 20 mm ((LxWxH)) 110 x 33 x 20 (without probe and TopSafe)
60 x 42 mm
80 x 90 x 75 mm (LxWxH)
20 x 24 x 140 mm (LxWxH)
Operating temperature
-20 to +70 °C
0 to +50 °C
-20 to +60 °C
-20 to +50 °C
0 to +60 °C
-10 to +50 °C
-30 to +50 °C
35 to +55 °C
-35 to +70 °C
-80 to +70 °C
-10 to +70 °C
-10 to +60 °C
Product-/housing material
ABS
TPE/PC + ABS/PC + ABS + 10% GF
ABS / TPE / PC, diecast zinc, stainless steel
Plastic
Stainless Steel
Protection class
IP65
IP55
IP68
IP67 with TopSafe
IP54
IP30
IP20
IP67
Standards
EN 13485
DIN EN 12830
2011/65/EU; EU-guideline 2014/30/EU
EU-guideline 2014/30/EU; DIN EN 12830; 2011/65/EU
EN 12830; CE 2014/30/EU; DIN EN 50581:2013; DIN EN 61326-1:2013; 2011/65/EU
EN 12830; CE 2014/30/EU; DIN EN 61326-1:2013; DIN EN 50581:2013; CFR 21 Part 11 (in use with testo ComSoft CFR-Software)
EN 12830; CE 2014/30/EU; DIN EN 50581:2013; DIN EN 61326-1:2013; CFR 21 Part 11 (in use with testo ComSoft CFR-Software)
Battery type
Button cell LR44
2 batteries type micro AAA 1.5 V (LR03)
2 lithium batteries (CR2032)
2 AAA micro batteries
1 x CR2032
3 AAA micro batteries
3V button cell (CR 2032)
4 x Button cell LR44
2 x 3V button cell (CR 2032)
3 x AIMn type AAA or Energizer
Lithium battery TLH-2450, 3V, exchangeable
4 x type AA batteries
9V block battery, 6F22
Built-in rechargeable battery: LI batttery 18650; Replaceable battery: 3 alkaline batteries AA
Reaction time
Approx. 30 s
t₉₉ = 10 s (Measured in moving liquid)
10 s (Measured in moving liquid)
8s
t₉₀ = 12 s
7 s
1 s
20 s
t₉₀ = 30 min
Authorizations
CE 2014/30/EU
CE; RTCA/DO-160G
PH Buffer
4.01
7.00
Diameter probe shaft
6 mm
5 mm
0.25 mm
Cable length
2.4 m
2 m
1.9 m
Product colour
White-Black
black/orange
Black
Memory
16.000 measuring values
1,000,000 measuring values
40,000 measuring values
Accuracy pressure
±0.5 % fs
±0.25 % fs
Probe connection
7 / 16 " - UNF
3 x 7/16" – UNF
2 x plug-in (NTC)
Field of view
30° x 23° (Standard lens), 12° x 9° (Telephoto lens, optional)
42° x 30°
31° x 23°
Focus
manual
Fixed focus
Minimum focus distance
< 0.1 m (Standard lens)
<0.5 m
Geometric resolution (IFOV)
1.7 mrad (standard lens), 0.7 mrad (telephoto lens)
2.3 mrad
3.4 mrad
Infrared resolution
320 x 240 pixel
160 x 120 pixels
SuperResolution (IFOV)
1.1 mrad (Standard lens), 0.4 mrad (Telephoto lens)
1.3 mrad
2.1 mrad
SuperResolution (Pixel)
640 x 480 pixels
320 x 240 pixels
Thermal sensitivity
˂ 40 mK
<0.05 °C (50 mK)
<0.08 °C (80 mK)
<0.1 °C (100 mK)
Minimum focus distance
< 0.4 m
min. 0.5 m
Calibration Type
Traceable Certificate
ISO17025
EIAC
GAC
Measuring range humidity
0 to 100 %RH
10 to 95 %RH
long-term stability: ±1 %RH / year ±0.06 %RH/K (k=1) ±2 %RH (2 to 98 %RH)
0 to 100 %RH*
* Not for condensing atmospheres. For continous use in high humidity (>80 %RH at ≤30°C for >12 h, >60 %RH at >30°C for 12 h), please contact us via our website. Please see the additional accuracy information for humidity in the instruction manual.
Accuracy Humidity
±1.0 %rF/year Drift ±1.0 %rF Hysterese ±2,0 %RH at 0 … 90 %RH at +25 °C ±0.03 %RH/K (k=1)
±3 %RH (2 to +98 %RH) at +25 °C ±0.03 %RH/K ±1 Digit
long-term stability: ±1 %RH / year ±3 %RH (10 to 95 %RH) ±0.06 %RH/K (k=1)
±3 %RH Remaining Range ±2 %RH + 1 Digit at 25 °C (10 to +90 %RH)
±3 %RH Remaining Range ±2 %RH + 1 Digit at +25 °C (10 to 90 %RH)
Measuring points
-18°/0°/+25°C
Point 1
0°/+50°/+100°C
0°/+30°/+60°C
20%/40%/90% RH at +25°C
Point 2
0°/+100°/+200°C
Point 3
20%/40%/85% RH at +25°C
20%/50%/75% RH at +25°C
-18°/0°/+40°C
0°/+25°/+50°C
0 to +60 °C (Short-term to +80 °C max. 5 min)
20%/40%/75% RH at +25°C
-18°/0°/+60°C
Measuring points selectable
Point 1
Point 2
Point 3
RESET
Add to Cart
testo 830-T1 Infrared thermometer
AED
352.05
352.05
AED
Add to Cart
Volume Flow - Calibration Certificate, ISO/17025. Single point: 300m³ to 3,500m³/h. GAC.
AED
300.00
300.0
AED
Add to Cart
Air Flow - Calibration Certificate, ISO/17025. 5 points: 1,5,10,15,20 m/s. GAC.
AED
300.00
300.0
AED
Add to Cart
Air Flow - Calibration Certificate, ISO/17025. 5 points: 1,2,4,8,10 m/s. GAC.
AED
300.00
300.0
AED
Add to Cart
Differential Pressure Gauge Calibration Certificate (0-100hPa), ISO/17025. Standard 9 points as per DKD-R 6-1, UUT Accuracy <0.6. EAIC.
AED
300.00
300.0
AED
Add to Cart
testoFlex Adapter
AED
291.83
291.83
AED
Add to Cart
Temperature instrument testo 106+TopSafe
AED
282.56
282.56
AED
Add to Cart
testo 184 T2 USB logger
AED
281.23
281.23
AED
Add to Cart
testo 174T, Mini Temp. Data Logger
AED
281.23
281.23
AED
Add to Cart
testo 103 Fold-away Thermometer
AED
264.04
264.04
AED
Add to Cart
Flat Cable Temperature Probe TC
AED
253.57
253.57
AED
Add to Cart
Pressure Gauge Calibration Certificate (-1 to 100bar), ISO/17025. Standard 9 points as per DKD-R 6-1, UUT Accuracy <0.6. GAC.
AED
250.00
250.0
AED
Add to Cart
Differential Pressure Gauge Calibration Certificate (0-100hPa), ISO/17025. Standard 5 points as per DKD-R 6-1, UUT Accuracy >0.6. EAIC.
AED
250.00
250.0
AED
Add to Cart
Temperature probe with stainless steel sleeve (TC Type K)
AED
248.96
248.96
AED
Add to Cart
testo 184 T1 USB Logger
AED
235.13
235.13
AED
Add to Cart
Mounting probe with aluminium sleeve
AED
225.91
225.91
AED
Add to Cart
Pressure Gauge Calibration Certificate (-1 to 100bar), ISO/17025. Standard 5 points as per DKD-R 6-1, UUT Accuracy >0.6. GAC.
AED
220.00
220.0
AED
Add to Cart
Thermal Imager Calibration Certificate, ISO/17025. Standard 3 points. EAIC.
AED
150.00
150.0
AED
Add to Cart
Testo 270 - Sensor tip
AED
150.00
150.0
AED
Add to Cart
E/RTC Marker (10 pc)
AED
138.31
138.31
AED
Load more