Guest
Login
Register
My Cart
(
0
)
My Wishlist
(
0
)
Filters
Home
Search
0
Wishlist
Account
Offers
Brands
Category
Orders
0
My Cart
$
0.00
0
My Wishlist
View Wishlist
Guest
My Account
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
0
Login
•
Register
Shop By Categories
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
My Cart
(
0
)
My Wishlist
(
0
)
MCD-USD-DIRECT
AED Public pricelist
$ MCD-USD-DIRECT
Shop
78 items found.
Products
HVAC
- 78 items
Pricelist :
MCD-USD-DIRECT
Public pricelist
MCD-USD-DIRECT
Price
-
FILTER
Measuring range
-50 to +275°C
+40 to +200 °C
-30 to +220 °C
-50 to +250 °C
-50 to +300 °C
-50 to +275 °C
0 to +60 °C (Short-term to +80 °C max. 5 min)
-30 to +650°C
-30 to +50 °C
-50 to +150 °C
-40 to +125 °C
-30 to +90 °C
-40 to +220 °C
-195 to +1350 °C
-40 to +1000 °C
-50 to +205 °C
-30 to +100°C; 0 to +650°C
-30 to +100° C; 0 to +650° C
-20 to +280 °C
-20 to +70 °C
-35 to +55 °C
-30 to +70 °C
-35 to +70 °C
-80 to +70 °C
-20 to +50 °C/td 0 to +50 °C
-10 to +70 °C/td -40 to +70 °C
-10 to +60 °C
-50 to +125 °C
-50 to +70 °C
-50 to +120 °C
-80 to +300 °C
-100 to +400 °C
-50 to +400 °C
-85 to +150 °C
-100 to +260 °C
0 to +80 °C
0 to +100 °C
+1 to +100 m/s
-40 to +1200 °C
-30 to +400°C
-50 to +350 °C
-150 to +150 hPa
0 to +200 hPa
-200 to +800 °C
-30 to +210 °C
-20 to +55 °C
-30 to +100°C; 0 to +350 °C (switchable)
-20 to +60 °C
-30 to +400 °C
-30 to +100 °C; 0 to +650 °C
-20 to +60 °C / 0 to 100 %RH
0 to 100 hPa
Accuracy
+/-0.5°C (-20 to +100°C)
+/-1% of mv (+100.0 to +275°C)
±1.0 °C (-50 to -20.1 °C)
±1.5 °C
±0.5 °C (-30 to +99.9 °C)
±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-30 to +99.9 °C) ±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-20 to +100 °C) ±1 % of mv (+100.1 to +275 °C) ±1.0 °C (-50 to -20.1 °C)
±1 °C (-50.0 to -30.1 °C) ±1 % of mv (Remaining Range) ±0.5 °C (-30.0 to +99.9 °C)
±1.0 °C (-50 to -30.1 °C) ±1 % of mv (+100 to +250 °C) ±0.5 °C (-30 to +99.9 °C)
±0.4 °C
±0.5 °C ±0.5 % of mv (-50 to -30 °C) ±0.5 °C ±0.5 % of mv (+70 to +300 °C) ±0.5 °C (-30 to +70 °C)
±1 % of mv (+100 to +275 °C) ±1.0 °C (-50 to -30.10 °C) ±0.5 °C (-30 to +99.9 °C)
±2 °C, ±2 % of m.v.; (greater value applies)
±0.5 °C
±0.3 °C
±0.5 % of mv (100 to +125 °C) ±0.4 °C Remaining Range ±0.2 °C (-25 to +80 °C)
±0.2 °C (-30 to +50 °C)
±0.5 °C (Remaining Range) ±0.2 °C (0 to +70 °C)
Class 1 ¹⁾
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
Class 1 According to standard EN 60584-2
±(0.5 + 0.5 % of mv) °C
Class 2 type K
±2 °C, ±2 % of mv
±0.5 °C (-20 to +70 °C)
±0.5 °C (-35 to +55 °C) ±1 Digit
±0.8 °C (-80 to -35.1 °C) ±0.5 °C (-35 to +70 °C)
±0.5 °C (at +25 °C)
±0.2 °C (-25 to +74.9 °C)
±0.5 % of mv (+100 to +150 °C)
±0.4 °C (Remaining Range)
±0.2 °C (-25 to +80 °C)
±0.2 °C (-25 to +70 °C)
±0.4 °C (-50 to -25 °C)
±(0.1 °C + 0.05 % of mv) (-40 to -0.001 °C)
±0.05 °C (0 to +100 °C)
±0.3 °C (-80 to -40.001 °C)
±(0.05 °C + 0.05 % of mv) (100.001 to 300 °C)
±(0.15 °C + 0.05 % of mv) (0 to +100 °C)
±(0.15 °C + 0.2 % of mv) (+100.01 to +350 °C)
±(0.5 °C + 0.5 % of mv) (+350.01 to +400 °C)
±(0.15 °C + 0.2 % of mv) (-100 to -0.01 °C)
±(0.3 °C + 0.3 % of mv) (-50 to +300 °C)
±(0.4 °C + 0.6 % of mv) (+300.01 to +400 °C)
0.01 °C
±(0.25 °C + 0.3% of reading) at -49.9 to +99.9 °C
±0.55 °C remaining measuring range
±1 °C (-20 to +85 °C)
±0.5 °C (0 to +99 °C)
±0.5 °C (-30 to +70 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C)
±1 °C (-50 to +99.9 °C)
±0.05 hPa (0 to 1.00 hPa) ±0.2 hPa + 1.5 % of mv (1.01 to +150 hPa)
±(0.1 hPa + 1.5 % of mv)± 1 digit (25.001 to 200 hPa); ±(0.3 Pa + 1 % of mv)± 1 digit (0 to 25 hPa)
±0.2 % of mv (Remaining Range) ±0.2 °C (-100 to +199.9 °C)
±2 °C or ±2 % of mv (Remaining Range) ±1.5 °C or ±1.5 % of mv (-20 to +210 °C)
±0.4 °C (-20 to +55 °C) ±1 Digit
±0.8 °C (-20 to 0 °C) ±0.5 °C (0 to +70 °C)
-35 to +70 °C
±0.5 °C (0 to +60 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C) ±2 °C or ±2 % of mv (-30 to 0 °C) (the higher value applies)
<= ±5 %RH (90 to < 100 %RH) <= ±1 %rF Hysterese <= ±3 %RH (10 to < 35 %RH) <= ±0.06 %RH/K (0 to 60 °C) <= ±3 %RH (65 to < 90 %RH) <= ±2 % of mv (35 to < 65 %RH) <= ±5 %RH (0 to < 10 %RH) <= ±1 %rF/year Drift
±0.5 °C ±1 Digit
±(0.1 hPa + 1.5 % of mv) ±1 Digit (25.001 to 200 hPa) ±(0.3 Pa + 1 % of mv) ±1 Digit (0 to 25 hPa)
±3.0 %RH at + 25 °C and < 20 and > 80 %RH ±1.0 %RH / year drift ±2.0 %RH at + 25 °C and 20 to 80 %RH ±1.0 %RH hysteresis // ±0.5 °C ±1 Digit
±2.0 %RH at +25 °C and 20 to 80 %RH ±1.0 %RH / year drift ±1.0 %RH hysteresis ±3.0 %RH at +25 °C and < 20 and > 80 %RH / ±0.5 °C
±0.5 °C / 0 to 100 %RH
± 0,5 °C
±0.03 hPa (0 to 0.30 hPa) ±0.05 hPa (0.31 to 1.00 hPa) ±(0.1 hPa + 1.5 % of m.v.) (1.01 to 100 hPa)
Resolution
0.1 °C
0.001 °C
0.01 °C
0.1 °C (1 to +100 °C)
0.01 hpa
0.001 to 0.1hPa
0.05 °C
-30 to +100°C; 0 to +350 °C (switchable)
0.001 hPa
0.1 °C / 0.1 %RH
Weight
162 g (incl. batteries) 210 g (incl. belt clip and batteries)
255 g
46 g (including battery)
198 g (incl. batteries)
165 g (incl. batteries)
115 g (with TopSafe) 65 g (without TopSafe)
210 g (incl.battery and Softcase) 154 g (incl. battery, without softcase)
80 g
156.6 g
135 g
69 g
66 g
824 g
595 g
240 g
36 g
1g
385 g
119 g
510 g
250 g
150 g
34 g
130 g
35 g
22 g
44 g
826 g
168 g
1 kg
1243 g
3435 g
258 g
528 g
606 g
322 g
628 g
726 g
261 g
346 g
670 g
182 g
154 g
1190 g
609 g
484 g
99 g
223 g
366 g
16 g
187 g
4800 g
400 g
3136 g
544 g
650 g
76 g
94 g
235 g
955 g
960 g
440 g
200 g
Operating temperature
-20 to +70 °C
0 to +50 °C
-20 to +60 °C
-20 to +50 °C
0 to +60 °C
-10 to +50 °C
-30 to +50 °C
35 to +55 °C
-35 to +70 °C
-80 to +70 °C
-10 to +70 °C
-10 to +60 °C
-5 to +45 °C
0 to +600 °C
-5 to +50 °C
-30 to 70 °C
Product-/housing material
ABS
TPE/PC + ABS/PC + ABS + 10% GF
ABS / TPE / PC, diecast zinc, stainless steel
Plastic
Stainless Steel
silicone
Metal housing
TPE PC
Reaction time
Approx. 30 s
t₉₉ = 10 s (Measured in moving liquid)
10 s (Measured in moving liquid)
8s
t₉₀ = 12 s
7 s
1 s
20 s
t₉₀ = 30 min
t₉₉: 60 s
t₉₉: 10 s
t₉₀ <45 s
240 s
30 s
Measuring range infrared
-30 to +250 °C
-30 to +400 °C
Accuracy infrared
±1.5 °C or ±1.5 % of mv (Remaining Range) ±2.0 °C (-20 to -0.1 °C) ±2.5 °C (-30 to -20.1 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C)
Infrared resolution
0.1 °C
320 x 240 pixel
160 x 120 pixels
Diameter probe shaft
6 mm
5 mm
0.25 mm
7 mm
8 mm
Product colour
White-Black
black/orange
Black
white
Black; silver
Measuring range humidity
0 to 100 %RH
10 to 95 %RH
long-term stability: ±1 %RH / year ±0.06 %RH/K (k=1) ±2 %RH (2 to 98 %RH)
0 to 100 %RH*
* Not for condensing atmospheres. For continous use in high humidity (>80 %RH at ≤30°C for >12 h, >60 %RH at >30°C for 12 h), please contact us via our website. Please see the additional accuracy information for humidity in the instruction manual.
Accuracy Humidity
±1.0 %rF/year Drift ±1.0 %rF Hysterese ±2,0 %RH at 0 … 90 %RH at +25 °C ±0.03 %RH/K (k=1)
±3 %RH (2 to +98 %RH) at +25 °C ±0.03 %RH/K ±1 Digit
long-term stability: ±1 %RH / year ±3 %RH (10 to 95 %RH) ±0.06 %RH/K (k=1)
±3 %RH Remaining Range ±2 %RH + 1 Digit at 25 °C (10 to +90 %RH)
±3 %RH Remaining Range ±2 %RH + 1 Digit at +25 °C (10 to 90 %RH)
< ±1 %RH / year drift at +25 °C ±2 %RH (2 to 98 %RH) at +25 °C ±0.03 %RH/K ±1 Digit
±1.8 %RH, +3 % of mv (at 25 °C, 5 % to 80 %RH) ±1 %rF/year Drift ±1 %rF Hysterese ±0.03 %RH/K (at 0 to 60 °C)
Hysteresis: ±1.0 %RH ±2.0 %RH (35 to 65 %RH) (at +25°C) long-term stability: ±1 %RH / year ±5 %RH (< 10 %RH or > 90 %RH) ±3.0 %RH (65 to 90 %RH) (at +25°C) ±3.0 %RH (10 to 35 %RH) (at +25°C)
long-term stability: ±1 %RH / year ±0.03 %RH/K (k=1) ±2 %RH (5 to 90 %RH)
±3 %RH (at 25 °C and < 20 %RH and > 80 %RH) ±5 %RH (90 to 100 %RH) ±1 %rF/year Drift ±3 %RH (65 to < 90 %RH) ±0.06 %RH/K (0 to 60 °C) ±1 %rF Hysterese ±2 %RH (20 to 80 %RH at 25 °C) ±2.0 %RH (35 to < 65 %RH)
Battery Life
100 days (at 15 mins measurement rate)
250 h with no illumination, no Bluetooth<sup>®</sup>; 100 h with illumination and Bluetooth<sup>®</sup>
approx. 1 year
With built-in rechargeable battery:; ≥220 h without Bluetooth®, without illumination; ≥120 h with Bluetooth® and illumination; With 3 AA batteries:; ≥145 h without Bluetooth®, without illumination; ≥75 h with Bluetooth® and illumination
100h
5 h
> 6h (Pumpe an, Displaybeleuchtung aus, bei 20°C)
1 year (15 min measuring cycle, +25 °C)
500 days (15 min measuring cycle, +25 °C)
5 h (without wireless connection)
15 h
Length probe shaft
335 mm
700 mm
430 mm
5 m
1,053 mm
1,000 mm
2.2 m
60 mm
350 mm
750 mm
Power supply
AC mains unit 100V to 240V (50 to 60 Hz)
Lithium-Ion rechargeable battery pack, 2600 mAh, 3.7 V
Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
Dimensions
length: 5000 mm, ø: 7 mm
60 x 38 x 18.5 mm
88 x 38 x 220 mm
Measuring Rate
1 min - 24 h
0.5s
RESET
Add to Cart
350mm pitot tube
$
166.10
166.1
USD
Add to Cart
testo 510i Smartprobe differential pressure meter
$
163.38
163.38
USD
Add to Cart
testo 110 NTC and Pt100 temperature measuring instrument with App connection
$
163.20
163.20000000000002
USD
Add to Cart
testo 405i Smartprobe thermal anemometer
$
161.94
161.94
USD
Add to Cart
testo 925 Temperature measuring instrument for TC Type K with App connection
$
149.39
149.39000000000001
USD
Add to Cart
Bluetooth handle for sensor heads
$
149.39
149.39000000000001
USD
Add to Cart
testo 605i - Thermohygrometer operated via smartphone (replacement for 0560 1605)
$
138.09
138.09
USD
Add to Cart
Pipe Wrap Probe NTC
$
128.05
128.05
USD
Add to Cart
testo 830-T2 Infrared Thermometer
$
128.05
128.05
USD
Add to Cart
testo Waterproof surface probe NTC with TUC connector
$
106.25
106.25
USD
Add to Cart
Air Probe NTC
$
104.20
104.2
USD
Add to Cart
Immersion / Penetration Probe NTC
$
101.69
101.69
USD
Add to Cart
Cable handle for sensor heads
$
101.69
101.69
USD
Add to Cart
testo 830-T1 Infrared thermometer
$
97.92
97.92
USD
Add to Cart
testoFlex Adapter
$
79.09
79.09
USD
Add to Cart
Clamp Probe for Measurements on Pipes
$
70.30
70.3
USD
Add to Cart
Connection hose, silicone, 5 m long
$
60.26
60.26
USD
Add to Cart
Thermal paper for printer 6 rolls
$
37.61
37.61
USD
All products are loaded.