AED
0.00
0
My Wishlist
View Wishlist
Guest
My Account
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
0
Login
•
Register
Shop By Categories
Home
Food Safety
Data Logger
Refrigeration
HVAC
Thermal Imager
Helpdesk
Aftersales Ticket
Repairs and warranty claims
Calibration Request
File in your calibration request.
Technical support
Related request for technical support.
Solution Support
Technical support for Pharma and food solution.
Calibration
Our Services
Catalog
Knowledge
Events
My Cart
(
0
)
My Wishlist
(
0
)
Shop
78 items found.
Products
HVAC
- 78 items
Pricelist :
Public pricelist
Public pricelist
Price
-
FILTER
Measuring range
-50 to +275°C
+40 to +200 °C
-30 to +220 °C
-50 to +250 °C
-50 to +300 °C
-50 to +275 °C
0 to +60 °C (Short-term to +80 °C max. 5 min)
-30 to +650°C
-30 to +50 °C
-50 to +150 °C
-40 to +125 °C
-30 to +90 °C
-40 to +220 °C
-195 to +1350 °C
-40 to +1000 °C
-50 to +205 °C
-30 to +100°C; 0 to +650°C
-30 to +100° C; 0 to +650° C
-20 to +280 °C
-20 to +70 °C
-35 to +55 °C
-30 to +70 °C
-35 to +70 °C
-80 to +70 °C
-20 to +50 °C/td 0 to +50 °C
-10 to +70 °C/td -40 to +70 °C
-10 to +60 °C
-50 to +125 °C
-50 to +70 °C
-50 to +120 °C
-80 to +300 °C
-100 to +400 °C
-50 to +400 °C
-85 to +150 °C
-100 to +260 °C
0 to +80 °C
0 to +100 °C
+1 to +100 m/s
-40 to +1200 °C
-30 to +400°C
-50 to +350 °C
-150 to +150 hPa
0 to +200 hPa
-200 to +800 °C
-30 to +210 °C
-20 to +55 °C
-30 to +100°C; 0 to +350 °C (switchable)
-20 to +60 °C
-30 to +400 °C
-30 to +100 °C; 0 to +650 °C
-20 to +60 °C / 0 to 100 %RH
Accuracy
+/-0.5°C (-20 to +100°C)
+/-1% of mv (+100.0 to +275°C)
±1.0 °C (-50 to -20.1 °C)
±1.5 °C
±0.5 °C (-30 to +99.9 °C)
±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-30 to +99.9 °C) ±1.0 % of mv (+100 to +220 °C)
±0.5 °C (-20 to +100 °C) ±1 % of mv (+100.1 to +275 °C) ±1.0 °C (-50 to -20.1 °C)
±1 °C (-50.0 to -30.1 °C) ±1 % of mv (Remaining Range) ±0.5 °C (-30.0 to +99.9 °C)
±1.0 °C (-50 to -30.1 °C) ±1 % of mv (+100 to +250 °C) ±0.5 °C (-30 to +99.9 °C)
±0.4 °C
±0.5 °C ±0.5 % of mv (-50 to -30 °C) ±0.5 °C ±0.5 % of mv (+70 to +300 °C) ±0.5 °C (-30 to +70 °C)
±1 % of mv (+100 to +275 °C) ±1.0 °C (-50 to -30.10 °C) ±0.5 °C (-30 to +99.9 °C)
±2 °C, ±2 % of m.v.; (greater value applies)
±0.5 °C
±0.3 °C
±0.5 % of mv (100 to +125 °C) ±0.4 °C Remaining Range ±0.2 °C (-25 to +80 °C)
±0.2 °C (-30 to +50 °C)
±0.5 °C (Remaining Range) ±0.2 °C (0 to +70 °C)
Class 1 ¹⁾
1) According to standard EN 60584-2, the accuracy of Class 1 refers to -40 to +1000 °C (Type K), Class 2 to -40 to +1200 °C (Type K), Class 3 to -200 to +40 °C (Type K).
Class 1 According to standard EN 60584-2
±(0.5 + 0.5 % of mv) °C
Class 2 type K
±2 °C, ±2 % of mv
±0.5 °C (-20 to +70 °C)
±0.5 °C (-35 to +55 °C) ±1 Digit
±0.8 °C (-80 to -35.1 °C) ±0.5 °C (-35 to +70 °C)
±0.5 °C (at +25 °C)
±0.2 °C (-25 to +74.9 °C)
±0.5 % of mv (+100 to +150 °C)
±0.4 °C (Remaining Range)
±0.2 °C (-25 to +80 °C)
±0.2 °C (-25 to +70 °C)
±0.4 °C (-50 to -25 °C)
±(0.1 °C + 0.05 % of mv) (-40 to -0.001 °C)
±0.05 °C (0 to +100 °C)
±0.3 °C (-80 to -40.001 °C)
±(0.05 °C + 0.05 % of mv) (100.001 to 300 °C)
±(0.15 °C + 0.05 % of mv) (0 to +100 °C)
±(0.15 °C + 0.2 % of mv) (+100.01 to +350 °C)
±(0.5 °C + 0.5 % of mv) (+350.01 to +400 °C)
±(0.15 °C + 0.2 % of mv) (-100 to -0.01 °C)
±(0.3 °C + 0.3 % of mv) (-50 to +300 °C)
±(0.4 °C + 0.6 % of mv) (+300.01 to +400 °C)
0.01 °C
±(0.25 °C + 0.3% of reading) at -49.9 to +99.9 °C
±0.55 °C remaining measuring range
±1 °C (-20 to +85 °C)
±0.5 °C (0 to +99 °C)
±0.5 °C (-30 to +70 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C)
±1 °C (-50 to +99.9 °C)
±0.05 hPa (0 to 1.00 hPa) ±0.2 hPa + 1.5 % of mv (1.01 to +150 hPa)
±(0.1 hPa + 1.5 % of mv)± 1 digit (25.001 to 200 hPa); ±(0.3 Pa + 1 % of mv)± 1 digit (0 to 25 hPa)
±0.2 % of mv (Remaining Range) ±0.2 °C (-100 to +199.9 °C)
±2 °C or ±2 % of mv (Remaining Range) ±1.5 °C or ±1.5 % of mv (-20 to +210 °C)
±0.4 °C (-20 to +55 °C) ±1 Digit
±0.8 °C (-20 to 0 °C) ±0.5 °C (0 to +70 °C)
-35 to +70 °C
±0.5 °C (0 to +60 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C) ±2 °C or ±2 % of mv (-30 to 0 °C) (the higher value applies)
<= ±5 %RH (90 to < 100 %RH) <= ±1 %rF Hysterese <= ±3 %RH (10 to < 35 %RH) <= ±0.06 %RH/K (0 to 60 °C) <= ±3 %RH (65 to < 90 %RH) <= ±2 % of mv (35 to < 65 %RH) <= ±5 %RH (0 to < 10 %RH) <= ±1 %rF/year Drift
±0.5 °C ±1 Digit
±(0.1 hPa + 1.5 % of mv) ±1 Digit (25.001 to 200 hPa) ±(0.3 Pa + 1 % of mv) ±1 Digit (0 to 25 hPa)
±3.0 %RH at + 25 °C and < 20 and > 80 %RH ±1.0 %RH / year drift ±2.0 %RH at + 25 °C and 20 to 80 %RH ±1.0 %RH hysteresis // ±0.5 °C ±1 Digit
±2.0 %RH at +25 °C and 20 to 80 %RH ±1.0 %RH / year drift ±1.0 %RH hysteresis ±3.0 %RH at +25 °C and < 20 and > 80 %RH / ±0.5 °C
±0.5 °C / 0 to 100 %RH
± 0,5 °C
Resolution
0.1 °C
0.001 °C
0.01 °C
0.1 °C (1 to +100 °C)
0.01 hpa
0.001 to 0.1hPa
0.05 °C
-30 to +100°C; 0 to +350 °C (switchable)
0.001 hPa
0.1 °C / 0.1 %RH
Weight
162 g (incl. batteries) 210 g (incl. belt clip and batteries)
255 g
46 g (including battery)
198 g (incl. batteries)
165 g (incl. batteries)
115 g (with TopSafe) 65 g (without TopSafe)
210 g (incl.battery and Softcase) 154 g (incl. battery, without softcase)
80 g
156.6 g
135 g
69 g
66 g
824 g
595 g
240 g
36 g
1g
385 g
119 g
510 g
250 g
150 g
34 g
130 g
35 g
22 g
44 g
826 g
168 g
1 kg
1243 g
3435 g
258 g
528 g
606 g
322 g
628 g
726 g
261 g
346 g
670 g
182 g
154 g
1190 g
609 g
484 g
99 g
223 g
366 g
16 g
187 g
4800 g
400 g
3136 g
544 g
650 g
76 g
94 g
235 g
955 g
960 g
440 g
200 g
Operating temperature
-20 to +70 °C
0 to +50 °C
-20 to +60 °C
-20 to +50 °C
0 to +60 °C
-10 to +50 °C
-30 to +50 °C
35 to +55 °C
-35 to +70 °C
-80 to +70 °C
-10 to +70 °C
-10 to +60 °C
-5 to +45 °C
0 to +600 °C
-5 to +50 °C
-30 to 70 °C
Product-/housing material
ABS
TPE/PC + ABS/PC + ABS + 10% GF
ABS / TPE / PC, diecast zinc, stainless steel
Plastic
Stainless Steel
silicone
Metal housing
TPE PC
Reaction time
Approx. 30 s
t₉₉ = 10 s (Measured in moving liquid)
10 s (Measured in moving liquid)
8s
t₉₀ = 12 s
7 s
1 s
20 s
t₉₀ = 30 min
t₉₉: 60 s
t₉₉: 10 s
t₉₀ <45 s
240 s
30 s
Measuring range infrared
-30 to +250 °C
-30 to +400 °C
Accuracy infrared
±1.5 °C or ±1.5 % of mv (Remaining Range) ±2.0 °C (-20 to -0.1 °C) ±2.5 °C (-30 to -20.1 °C)
±1.5 °C or ±1.5 % of mv (+0.1 to +400 °C)
Infrared resolution
0.1 °C
320 x 240 pixel
160 x 120 pixels
Diameter probe shaft
6 mm
5 mm
0.25 mm
7 mm
8 mm
Product colour
White-Black
black/orange
Black
white
Black; silver
Measuring range humidity
0 to 100 %RH
10 to 95 %RH
long-term stability: ±1 %RH / year ±0.06 %RH/K (k=1) ±2 %RH (2 to 98 %RH)
0 to 100 %RH*
* Not for condensing atmospheres. For continous use in high humidity (>80 %RH at ≤30°C for >12 h, >60 %RH at >30°C for 12 h), please contact us via our website. Please see the additional accuracy information for humidity in the instruction manual.
Accuracy Humidity
±1.0 %rF/year Drift ±1.0 %rF Hysterese ±2,0 %RH at 0 … 90 %RH at +25 °C ±0.03 %RH/K (k=1)
±3 %RH (2 to +98 %RH) at +25 °C ±0.03 %RH/K ±1 Digit
long-term stability: ±1 %RH / year ±3 %RH (10 to 95 %RH) ±0.06 %RH/K (k=1)
±3 %RH Remaining Range ±2 %RH + 1 Digit at 25 °C (10 to +90 %RH)
±3 %RH Remaining Range ±2 %RH + 1 Digit at +25 °C (10 to 90 %RH)
< ±1 %RH / year drift at +25 °C ±2 %RH (2 to 98 %RH) at +25 °C ±0.03 %RH/K ±1 Digit
±1.8 %RH, +3 % of mv (at 25 °C, 5 % to 80 %RH) ±1 %rF/year Drift ±1 %rF Hysterese ±0.03 %RH/K (at 0 to 60 °C)
Hysteresis: ±1.0 %RH ±2.0 %RH (35 to 65 %RH) (at +25°C) long-term stability: ±1 %RH / year ±5 %RH (< 10 %RH or > 90 %RH) ±3.0 %RH (65 to 90 %RH) (at +25°C) ±3.0 %RH (10 to 35 %RH) (at +25°C)
long-term stability: ±1 %RH / year ±0.03 %RH/K (k=1) ±2 %RH (5 to 90 %RH)
Battery Life
100 days (at 15 mins measurement rate)
250 h with no illumination, no Bluetooth<sup>®</sup>; 100 h with illumination and Bluetooth<sup>®</sup>
approx. 1 year
With built-in rechargeable battery:; ≥220 h without Bluetooth®, without illumination; ≥120 h with Bluetooth® and illumination; With 3 AA batteries:; ≥145 h without Bluetooth®, without illumination; ≥75 h with Bluetooth® and illumination
100h
5 h
> 6h (Pumpe an, Displaybeleuchtung aus, bei 20°C)
1 year (15 min measuring cycle, +25 °C)
500 days (15 min measuring cycle, +25 °C)
5 h (without wireless connection)
15 h
Length probe shaft
335 mm
700 mm
430 mm
5 m
1,053 mm
1,000 mm
2.2 m
60 mm
350 mm
750 mm
Power supply
AC mains unit 100V to 240V (50 to 60 Hz)
Lithium-Ion rechargeable battery pack, 2600 mAh, 3.7 V
Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
Dimensions
length: 5000 mm, ø: 7 mm
60 x 38 x 18.5 mm
88 x 38 x 220 mm
Measuring Rate
1 min - 24 h
0.5s
RESET
Add to Cart
testo 835-T2 Infrared Thermometer
AED
2,360.50
2360.5
AED
Add to Cart
testo 535 Digital CO₂ measuring instrument with App connection
AED
2,291.34
2291.34
AED
Add to Cart
Precise temperature-humidity probe,cable
AED
2,291.34
2291.34
AED
Add to Cart
High-Precision Pt100 Probe with TUC
AED
2,291.34
2291.34
AED
Add to Cart
testo 425 Digital hot wire anemometer with App connection
AED
2,286.73
2286.73
AED
Add to Cart
Vane probe (Ø 100 mm; 0,3m/s), BT
AED
2,277.51
2277.51
AED
Add to Cart
testo 417 Kit 1 vane anemometer with measurement funnels
AED
2,171.47
2171.4700000000003
AED
Add to Cart
testo 440 dP air velocity and IAQ meter incl. integrated differential pressure sensor
AED
2,166.86
2166.86
AED
Add to Cart
Vane probe (Ø 100 mm; 0,3m/s), cable
AED
2,111.54
2111.54
AED
Add to Cart
testo 512-2 Digital differential pressure measuring instrument with App connection
AED
2,106.93
2106.93
AED
Add to Cart
testo 512-1 Digital differential pressure measuring instrument with App connection
AED
2,106.93
2106.93
AED
Add to Cart
CO2 probe head incl. °C und %rF
AED
2,093.10
2093.1
AED
Add to Cart
CO probe (digital) - with Bluetooth
AED
1,913.30
1913.3
AED
Add to Cart
testo 545 Digital Lux meter with App connection
AED
1,871.80
1871.8
AED
Add to Cart
testo 417 Digital 100 mm vane anemometer with App connection
AED
1,774.98
1774.98
AED
Add to Cart
CO probe, cable
AED
1,747.32
1747.32
AED
Add to Cart
Lux probe with fixed cable (cable length 1.4 m) and calibration protocol
AED
1,719.66
1719.66
AED
Add to Cart
testo Stainless steel pitot tube,1000 mm, Ø 7 mm
AED
1,692.00
1692.0
AED
Add to Cart
Sensor head Vane probe (Ø 100mm)
AED
1,627.45
1627.45
AED
Add to Cart
testo 440 Air velocity and IAQ meter
AED
1,604.40
1604.4
AED
Load more